Electro Surgical Cautry 400 Watt

GLOWCELL INSTRUMENTS new SMART4 is the most versatile Electro Surgical Generator. It offers features and performance, never before available in a single generator. The SMART4 has spray and coagulation which rivals the best spark gap generators and with minimum cutting effect. The blend gives a good Hemostasis effect than cutting and pure cut is exceptionally smooth and starts promptly even in irrigated procedures. The isolated bipolar output, which has a non-sparking characteristic, is ideal for microsurgery, Neuro Surgery, Laproscopy and other applications. SMART4 meets the surgeon’s needs in the wide range of general procedures and in specialties including Gynecology, Urology, Neurology, Thorasic , Plastic and Reconstructive Surgery.

PRODUCT FEATURES

Cut Mode

  • PURE – A high-frequency alternating current yields smooth, rapid cuts that evoke little to no hemostasis.
  • BLEND 1 – Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.
  • BLEND 2 – The mode is used for the vaporization of prostatic tissue or any fat tissue. The higher output wattage gives fast cutting effect.
  • ENDOCUT – The mode is used to automatically control cut system to reduce the complication rate of endoscopic sphincterotamy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode.
  • Coag Mode

  • SPRAY – Spray output is made for direct coagulation at the tissue with spark. This spark does not give any cutting effect as its crest Factor is high.
  • FORCE — This modes is greater degree of homeostasis and covers all demands of standard coagulation. This produce the fine tune waveform that creates superficial resistance in the tissue resulting in superior coagulation where the tissue destroyed byhyper evaporation.
  • FUIGURATE – Sparking the tissue to lead to coagulation. There is no tissue electrode contacts; rather, voltage is raised in order to incite a spark between electrodesin order to coagulate the tissue in between.
  • DESICCATE – Coagulation in which the active electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries It ensures pinpoint desiccation with less destruction of peripheral tissue.
  • Bipolar Mode

  • MICRO – High Voltage force coagulation for special purpose when speed is required.
  • MACRO – For highly precise control over coagulation process and privations of carbonization.
  • CU- TThi s Bipolar CUT technology nearly eliminate excessive current, even during precision cutting in minute tissue structure.
  • AUTO – Coagulation start by pressing the footswitch and stops output and audio signal automatically when the tissue is Coagulated.
  • PRODUCT TECHNICAL SPECIFICATION

    CUT
    MODE MAX POWER LOAD CREAST FACTOR
    Pure Cut 400 W 300 Q 1.5
    Blend 1 250 W 300 Q 1.5
    Blend 2 200 W 300 Q 1.5
    Endocut 99% 300 Q 1.5
    COAG
    MODE MAX POWER LOAD CREAST FACTOR
    Spray 120 W 300 Q 7
    Force 120 W 300 Q 6.5
    Fulgurate 150 W 300 Q 6
    Desiccate 150 W 300 Q 6
    BIPOLAR
    MODE MAX POWER LOAD CREAST FACTOR
    Micro 80 W 100 Q 1.5
    Macro 80 W 100 Q 1.5
    Cut 100 W 100 Q 1.5
    Auto 100 W 100 Q 1.5

    Safety Features

  • Protection Class According to
    EN 60601-1
  • HF leakage current <150mA
  • Body Protected and Cardiac
    Protected Design
  • Patient Plate Monitoring System
  • Product Specification

  • 99 User settable program mode
  • Frequency: 480khz
  • Display : 7segment LED
  • Weight: 7. 5 Kg (Approx)
  • Dimension : 410mm (L) x 355 mm (W) x 155 mm (H)
  • Input Supply Voltage 230V (+/-15%) 50 Hz
  • Separates Monopolar & Bipolar foot switches
  • STANDARD ACCESSORIES